Skip to main content

Table 6 Solutions of UP-2 with different values of S ′

From: Determination of Target Values of Engineering Characteristics in QFD Using Uncertain Programming

S ′

x 1

x 2

x 3

x 4

x 5

E(C V )

0.1

0

0.4762

0

0

0

5.0001

0.2

0

0.9524

0

0

0

10.0002

0.3

0.5625

1

0

0

0

16.1250

0.4

1

1

0

0.1304

0

22.4575

0.5

1

1

0

0.5652

0

28.9795

0.6

1

1

0

1

0

35.5000

0.7

1

1

0

1

0.7693

42.0390

0.8

1

1

0.2593

1

1

50.4825

0.9

1

1

0.6296

1

1

59.7425

1

1

1

1

1

1

69.0000